Passive_DAS_T00013A0376

[[- PAGE_NUM=1 -]]

Passive DAS

PASSIVE LOW-PIM

COMPONENTS

FOR DISTRIBUTED

ANTENNA SYSTEMS

In-Building Coverage Solutions
by Telegärtner

LOW-PIMFUTURE-PROOF

[[- PAGE_NUM=2 -]]

2 TELEGÄRTNER PASSIVE DAS

Coverage is one critical requirement for deploying
mobile communication networks. This is true for all cell
architectures such as macro, micro, small and pico cells.

For reaching all users in a cellular network, in-building
coverage also needs to be ensured. Especially on the lower
floors in large buildings, network availability is limited,

if the building is not equipped with a Distributed Antenna
System. This solution is implemented to achieve optimal
coverage and provide maximum capacity in larger premises
such as shopping malls, stadiums, concert halls, airports,
hotels, (underground) train stations or large office buildings.

DISTRIBUTED

ANTENNA

SYSTEMS

For reliable coverage.
Today we want to be connected everywhere. Therefore,
mobile radio connections must not end at the entrance to
larger buildings. Especially in large premises, there is a need
for comprehensive network coverage for good signals –
always and everywhere.

[[- PAGE_NUM=3 -]]

PASSIVE DAS TELEGÄRTNER 3

Telegärtner offers passive DAS components such as
Power Splitters, Couplers, Tappers or Termination Loads
to support its customers with suitable solutions. A broad
range of coaxial RF components is available to cover the
need for such products and to meet the heterogeneous
requirements of each site. Due to the tendency of higher
requirements regarding PIM levels, Telegärtner only offers

low-PIM components (≤ -161 dBc) in the standard
portfolio. Furthermore, future-proof components
for frequencies up to 3.8 GHz are available for 5G
applications. Due to the need for short delivery times,
Telegärtner aims to be ready for shipment within
24 hours for parts in stock. Customized solutions
are available on demand.

Power Splitter

Directional Coupler

Tapper

Hybrid Coupler

DAS

[[- PAGE_NUM=4 -]]

4 TELEGÄRTNER PASSIVE DAS

Num
ber of Ports

2/2

3/3

4/4

POWER

SPLITTERS

Power Splitters with N or 4.3-10 connector
interfaces.
Power Splitters are used to split a signal equally
from one input port through two, three or four
output ports. All listed splitters are suitable for
low-PIM applications due to the low PIM level
of ≤ -161 dBc and are also characterized by high
power capacity and low VSWR.

Frequency Range
340 –2700 MHz,
698–2700 MHz,
575–3800 MHz

2-way, 3-way
or 4-way splits

low-PIM

[[- PAGE_NUM=5 -]]

PASSIVE DAS TELEGÄRTNER 5

Part NumberConnector
Interface
Frequency RangeSplitsSplit
Loss
PIM
(@2 × 43 dBm)
Av. Power
Rating
Environmental
J01029A0019N female340 –2700 MHz2-way3 dB≤ -161 dBc200 WIP65
J01029A0020N female340 –2700 MHz3-way4.8 dB≤ -161 dBc200 WIP65
J01029A0021N female340 –2700 MHz4-way6 dB≤ -161 dBc200 WIP65
J01029A0004N female698–2700 MHz2-way3 dB≤ -161 dBc200 WIP65
J01029A0005N female698–2700 MHz3-way4.8 dB≤ -161 dBc200 WIP65
J01029A0006N female698–2700 MHz4-way6 dB≤ -161 dBc200 WIP65
J01029A0007N female575–3800 MHz2-way3 dB≤ -161 dBc200 WIP65
J01029A0008N female575–3800 MHz3-way4.8 dB≤ -161 dBc200 WIP65
J01029A0009N female575–3800 MHz4-way6 dB≤ -161 dBc200 WIP65
J 014 47A0 0304.3-10 female340 –2700 MHz2-way3 dB≤ -161 dBc300 WIP65
J 014 47A0 0314.3-10 female340 –2700 MHz3-way4.8 dB≤ -161 dBc300 WIP65
J 014 47A0 0324.3-10 female340 –2700 MHz4-way6 dB≤ -161 dBc300 WIP65
J01447A00014.3-10 female698–2700 MHz2-way3 dB≤ -161 dBc300 WIP65
J01447A00024.3-10 female698–2700 MHz3-way4.8 dB≤ -161 dBc300 WIP65
J01447A00034.3-10 female698–2700 MHz4-way6 dB≤ -161 dBc300 WIP65
J01447A00044.3-10 female575–3800 MHz2-way3 dB≤ -161 dBc300 WIP65
J01447A00054.3-10 female575–3800 MHz3-way4.8 dB≤ -161 dBc300 WIP65
J01447A00064.3-10 female575–3800 MHz4-way6 dB≤ -161 dBc300 WIP65
H06000A0084L-Type Bracket for Splitters included

4.3-10 Connector
Interface

N Connector
Interface

J01447A0001

J01029A0004J01029A0005J01029A0006

J01447A0002J01447A0003

[[- PAGE_NUM=6 -]]

6 TELEGÄRTNER PASSIVE DAS

DIRECTIONAL

COUPLERS

Directional Couplers with N or 4.3-10 connector
interfaces.
Directional Couplers can be used to split a signal into
either two equal or into two unequal shares. This is
provided with high isolation between the coupled
and the output port. Directional couplers provide
superior characteristics in terms of directivity and
return loss. All listed directional couplers are suitable
for low-PIM applications due to the low PIM level of
≤ -161 dBc.

Coupling Ratio
up to 30 dB

J01024A0016

J01024A0017

Frequency Range
340 –2700 MHz,
698–2700 MHz,
575–3800 MHz

low-PIM

[[- PAGE_NUM=7 -]]

PASSIVE DAS TELEGÄRTNER 7

Part NumberConnector
Interface
Frequency RangeCoupling RatioPIM
(@2 × 43 dBm)
Av. Power
Rating
Environmental
J01024A0031N female340 –2700 MHz3 dB≤ -161 dBc200 WIP65
J01024A0032N female340 –2700 MHz6 dB≤ -161 dBc200 WIP65
J01024A0033N female340 –2700 MHz8 dB≤ -161 dBc200 WIP65
J01024A0034N female340 –2700 MHz10 dB≤ -161 dBc200 WIP65
J01024A0035N female340 –2700 MHz12 dB≤ -161 dBc200 WIP65
J01024A0036N female340 –2700 MHz15 dB≤ -161 dBc200 WIP65
J01024A0037N female340 –2700 MHz20 dB≤ -161 dBc200 WIP65
J01024A0038N female340 –2700 MHz30 dB≤ -161 dBc200 WIP65
J01024A0030N female698–2700 MHz3 dB≤ -161 dBc200 WIP65
J01024A0016N female698–2700 MHz6 dB≤ -161 dBc200 WIP65
J01024A0017N female698–2700 MHz8 dB≤ -161 dBc200 WIP65
J01024A0018N female698–2700 MHz10 dB≤ -161 dBc200 WIP65
J01024A0019N female698–2700 MHz12 dB≤ -161 dBc200 WIP65
J01024A0020N female698–2700 MHz15 dB≤ -161 dBc200 WIP65
J01024A0021N female698–2700 MHz20 dB≤ -161 dBc200 WIP65
J01024A0022N female698–2700 MHz30 dB≤ -161 dBc200 WIP65
J01024A0039N female575–3800 MHz3 dB≤ -161 dBc200 WIP65
J01024A0023N female575–3800 MHz6 dB≤ -161 dBc200 WIP65
J01024A0024N female575–3800 MHz8 dB≤ -161 dBc200 WIP65
J01024A0025N female575–3800 MHz10 dB≤ -161 dBc200 WIP65
J01024A0026N female575–3800 MHz12 dB≤ -161 dBc200 WIP65
J01024A0027N female575–3800 MHz15 dB≤ -161 dBc200 WIP65
J01024A0028N female575–3800 MHz20 dB≤ -161 dBc200 WIP65
J01024A0029N female575–3800 MHz30 dB≤ -161 dBc200 WIP65
J 014 47A0 0344.3-10 female340 –2700 MHz3 dB≤ -161 dBc300 WIP65
J 014 47A0 0354.3-10 female340 –2700 MHz6 dB≤ -161 dBc300 WIP65
J 014 47A0 0364.3-10 female340 –2700 MHz8 dB≤ -161 dBc300 WIP65
J 014 47A0 0374.3-10 female340 –2700 MHz10 dB≤ -161 dBc300 WIP65
J 014 47A0 0384.3-10 female340 –2700 MHz12 dB≤ -161 dBc300 WIP65
J 014 47A0 0394.3-10 female340 –2700 MHz15 dB≤ -161 dBc300 WIP65
J 014 47A0 0 4 04.3-10 female340 –2700 MHz20 dB≤ -161 dBc300 WIP65
J 014 47A0 0 414.3-10 female340 –2700 MHz30 dB≤ -161 dBc300 WIP65
J 014 47A0 0334.3-10 female698–2700 MHz3 dB≤ -161 dBc300 WIP65
J01447A00074.3-10 female698–2700 MHz6 dB≤ -161 dBc300 WIP65
J01447A00084.3-10 female698–2700 MHz8 dB≤ -161 dBc300 WIP65
J01447A00094.3-10 female698–2700 MHz10 dB≤ -161 dBc300 WIP65
J01447A00104.3-10 female698–2700 MHz12 dB≤ -161 dBc300 WIP65
J01447A00114.3-10 female698–2700 MHz15 dB≤ -161 dBc300 WIP65
J01447A00124.3-10 female698–2700 MHz20 dB≤ -161 dBc300 WIP65
J01447A00134.3-10 female698–2700 MHz30 dB≤ -161 dBc300 WIP65
J 014 47A0 0544.3-10 female575–3800 MHz3 dB≤ -161 dBc300 WIP65
J014 47A00144.3-10 female575–3800 MHz6 dB≤ -161 dBc300 WIP65
J01447A00154.3-10 female575–3800 MHz8 dB≤ -161 dBc300 WIP65
J01447A00164.3-10 female575–3800 MHz10 dB≤ -161 dBc300 WIP65
J01447A00174.3-10 female575–3800 MHz12 dB≤ -161 dBc300 WIP65
J01447A00184.3-10 female575–3800 MHz15 dB≤ -161 dBc300 WIP65
J014 47A00194.3-10 female575–3800 MHz20 dB≤ -161 dBc300 WIP65
J 014 47A0 0204.3-10 female575–3800 MHz30 dB≤ -161 dBc300 WIP65

[[- PAGE_NUM=8 -]]

8 TELEGÄRTNER PASSIVE DAS

TAPPERS

Tappers with N or 4.3-10 connector interfaces.
Tappers are used to divide a signal into unequal
parts respectively to tap off a signal portion
from a main transmission line. Tappers are
differentiated from couplers by being able to
split signals only in defined ratios and without
directivity. Tappers are generally smaller and
less expensive than couplers, but also come
with a low PIM level of ≤ -161 dBc and high
power rating.

J01029A0012

J 014 47A0 023

Frequency Range
340-960 MHz / 1710-2700 MHz or
698-960 MHz / 1710-2700 MHz

Coupling Ratio
up to 30 dB

low-PIM

[[- PAGE_NUM=9 -]]

PASSIVE DAS TELEGÄRTNER 9

Part NumberConnector
Interface
Frequency RangeCoupling
Ratio
PIM
(@2 × 43 dBm)
Av. Power
Rating
Environmental
J01029A0026N female340–960 / 1710–2700 MHz3 dB≤ -161 dBc200 WIP65
J01029A0027N female340–960 / 1710–2700 MHz6 dB≤ -161 dBc200 WIP65
J01029A0028N female340–960 / 1710–2700 MHz8 dB≤ -161 dBc200 WIP65
J01029A0029N female340–960 / 1710–2700 MHz10 dB≤ -161 dBc200 WIP65
J01029A0030N female340–960 / 1710–2700 MHz13 dB≤ -161 dBc200 WIP65
J01029A0031N female340–960 / 1710–2700 MHz15 dB≤ -161 dBc200 WIP65
J01029A0032N female340–960 / 1710–2700 MHz20 dB≤ -161 dBc200 WIP65
J01029A0033N female340–960 / 1710–2700 MHz30 dB≤ -161 dBc200 WIP65

J01029A0025N female698–960 / 1710–2700 MHz3 dB≤ -161 dBc200 WIP65
J01029A0012N female698–960 / 1710–2700 MHz6 dB≤ -161 dBc200 WIP65
J01029A0013N female698–960 / 1710–2700 MHz8 dB≤ -161 dBc200 WIP65
J01029A0014N female698–960 / 1710–2700 MHz10 dB≤ -161 dBc200 WIP65
J01029A0015N female698–960 / 1710–2700 MHz13 dB≤ -161 dBc200 WIP65
J01029A0016N female698–960 / 1710–2700 MHz15 dB≤ -161 dBc200 WIP65
J01029A0017N female698–960 / 1710–2700 MHz20 dB≤ -161 dBc200 WIP65
J01029A0018N female698–960 / 1710–2700 MHz30 dB≤ -161 dBc200 WIP65

J 014 47A0 0 454.3-10 female340–960 / 1710–2700 MHz3 dB≤ -161 dBc300 WIP65
J 014 47A0 0 4 64.3-10 female340–960 / 1710–2700 MHz6 dB≤ -161 dBc300 WIP65
J01447A00474.3-10 female340–960 / 1710–2700 MHz8 dB≤ -161 dBc300 WIP65
J 014 47A0 0 4 84.3-10 female340–960 / 1710–2700 MHz10 dB≤ -161 dBc300 WIP65
J 014 47A0 0 494.3-10 female340–960 / 1710–2700 MHz13 dB≤ -161 dBc300 WIP65
J 014 47A0 0504.3-10 female340–960 / 1710–2700 MHz15 dB≤ -161 dBc300 WIP65
J 014 47A0 0514.3-10 female340–960 / 1710–2700 MHz20 dB≤ -161 dBc300 WIP65
J 014 47A0 0524.3-10 female340–960 / 1710–2700 MHz30 dB≤ -161 dBc300 WIP65

J 014 47A0 0534.3-10 female698–960 / 1710–2700 MHz3 dB≤ -161 dBc300 WIP65
J 014 47A0 0234.3-10 female698–960 / 1710–2700 MHz6 dB≤ -161 dBc300 WIP65
J 014 47A0 0244.3-10 female698–960 / 1710–2700 MHz8 dB≤ -161 dBc300 WIP65
J 014 47A0 0254.3-10 female698–960 / 1710–2700 MHz10 dB≤ -161 dBc300 WIP65
J01447A00264.3-10 female698–960 / 1710–2700 MHz13 dB≤ -161 dBc300 WIP65
J 014 47A0 0274.3-10 female698–960 / 1710–2700 MHz15 dB≤ -161 dBc300 WIP65
J 014 47A0 0284.3-10 female698–960 / 1710–2700 MHz20 dB≤ -161 dBc300 WIP65
J 014 47A0 0294.3-10 female698–960 / 1710–2700 MHz30 dB≤ -161 dBc300 WIP65
H06000A0085W-Type Bracket for Tappers included

[[- PAGE_NUM=10 -]]

10 TELEGÄRTNER PASSIVE DAS

HYBRID

COUPLERS

Hybrid Couplers with N or 4.3-10 connector
interfaces.
Hybrid Couplers are basically used for either
splitting a signal into equal shares with high
port isolation or to combine signals within
the same frequency band. As for most other
components, Telegärtner concentrates on low
PIM, low VSWR and low insertion loss.

Frequency Range
340 –2700 MHz,
698–2700 MHz,
575–3800 MHz

Number of Ports

2/2

3/3

4/4

low-PIM

[[- PAGE_NUM=11 -]]

PASSIVE DAS TELEGÄRTNER 11

Part NumberConnector
Interface
Frequency RangeNo. of Ports
In/Out
PIM
(@2 × 43 dBm)
Av. Power RatingEnvironmental
J01029A0022N female340 –2700 MHz2/2≤ -161 dBc200 WIP65
J01029A0010N female698–2700 MHz2/2≤ -161 dBc200 WIP65
J01029A0011N female575–3800 MHz2/2≤ -161 dBc200 WIP65
J01029A0023N female698–2700 MHz3/3≤ -155 dBc200 WIP65
J01029A0024N female698–2700 MHz4/4≤ -161 dBc200 WIP65

J 014 47A0 0 424.3-10 female340 –2700 MHz2/2≤ -161 dBc300 WIP65
J 014 47A0 0214.3-10 female698–2700 MHz2/2≤ -161 dBc300 WIP65
J 014 47A0 0224.3-10 female575–3800 MHz2/2≤ -161 dBc300 WIP65
J 014 47A0 0 434.3-10 female698–2700 MHz3/3≤ -155 dBc300 WIP65
J01447A00444.3-10 female698–2700 MHz4/4≤ -161 dBc300 WIP65

J 014 47A0 0 43

J01447A0044

J 014 47A0 021

J01029A0010

[[- PAGE_NUM=12 -]]

12 TELEGÄRTNER PASSIVE DAS

TERMINATION

LOADS

Termination Loads with N or 4.3-10 connector interfaces.
Termination Loads are applied to terminate remaining power on a transmission
line that is not needed, e.g. for testing purposes or diagnostics. The target
is also not to reflect any power. Loads can likewise be used to terminate an
unused port of a hybrid couplers when it is used as directional coupler. Besides
standard loads, Telegärtner also offers low-PIM Loads with 4.3-10 plugs for
terminating power up to 200 W.

J01444A0004

4.3-10 low-PIM versions
up to 200 W Power Rating

low-PIM

[[- PAGE_NUM=13 -]]

PASSIVE DAS TELEGÄRTNER 13

Part NumberConnector InterfaceFrequency RangePower RatingPIM
(@2 × 43 dBm)
J01026A0012N male0–6 GHz1 W–
J01026A0010N male0 –18 GHz2 W–
J01026A0022N male0–6 GHz10 W–

J01444A00014.3-10 male0–6 GHz1 W–
J01444A00004.3-10 male (Screw)0 –7. 5 G H z2 W–
J01444A30004.3-10 male (Push-Pull)0 –7. 5 G H z2 W–
J01444A00024.3-10 male0–6 GHz10 W–

J01444A00114.3-10 male650–3000 MHz10 W≤ -161 dBc
J01444A00034.3-10 male650–3000 MHz30 W≤ -161 dBc
J01444A00044.3-10 male698–2700 MHz200 W≤ -161 dBc
H06000A0083Bracket for High Power Low PIM Loads & Attenuators

J01444A0000

J01026A0022

J01444A0003

[[- PAGE_NUM=14 -]]

14 TELEGÄRTNER PASSIVE DAS

ATTENUATORS

Attenuators with N or 4.3-10 connector interfaces.
Attenuators are used where power needs to be reduced to reach a certain
transmitted power level at a defined point in a transmission line. Attenuators
can virtually simulate longer transmission distances with the same insertion
loss. Besides standard attenuators, Telegärtner also offers low-PIM attenuators
(≤ -161 dBc) with 4.3-10 interface for higher power up to 100 W and attenuation
up to 30 dB.

4.3-10 low-PIM versions
up to 100 W Power Rating
Attenuation
up to 30 dB

J01444A0008

low-PIM

[[- PAGE_NUM=15 -]]

PASSIVE DAS TELEGÄRTNER 15

Part NumberConnector InterfaceFrequency RangePower RatingAttenuationPIM
(@2 × 43 dBm)
J01026A0018N male to N female0 –10 GHz2 W3 dB–
J01026A0019N male to N female0 –10 GHz2 W6 dB–
J01026A0020N male to N female0 –10 GHz2 W10 dB–
J01026A0021N male to N female0 –10 GHz2 W20 dB–

J01444A00054.3-10 male to 4.3-10 female698–2700 MHz50 W10 dB≤ -161 dBc
J01444A00064.3-10 male to 4.3-10 female698–2700 MHz50 W20 dB≤ -161 dBc
J01444A00074.3-10 male to 4.3-10 female698–2700 MHz50 W30 dB≤ -161 dBc
J01444A00084.3-10 male to 4.3-10 female698–2700 MHz100 W10 dB≤ -161 dBc
J01444A00094.3-10 male to 4.3-10 female698–2700 MHz100 W20 dB≤ -161 dBc
J01444A00104.3-10 male to 4.3-10 female698–2700 MHz100 W30 dB≤ -161 dBc
H06000A0083Bracket for High Power Low PIM Loads & Attenuators

J01026A0020

[[- PAGE_NUM=16 -]]

Your distributor:

Telegärtner
Karl Gärtner GmbH
Lerchenstr. 35
D-71144 Steinenbronn
Tel. +49 71 57 / 1 25- 0
Fax +49 71 57 / 1 25- 5120
info@telegaertner.com
www.telegaertner.com

Would you like to discover our entire
portfolio for Antenna Line Products?
Please have a look at our catalogue „Components
for Mobile Communication Networks“ on our
website www.telegaertner.com/go/MCS

T00013A0376

[[- METADATA -]]

n_pages: 16
fingerprint: f134dd7f3db3e549af424a1522ac6312
format_version: 1.6
pdf_is_linearized: true
pdf_is_acroform: false
pdf_is_xfa: false
pdf_is_collection: false
created_dt: 2019-10-11T14:04:50+0200
creator: Adobe InDesign 14.0 (Windows)
producer: Adobe PDF Library 15.0
modified_dt: 2020-03-09T11:53:29+0100